Skip to content

    Slip resistance ratings for stone: R values, PTV and specifying

    For stone floors in the UK, a wet pendulum PTV of 36 or more means low slip potential. R9–R13 ramp ratings do not convert to PTV, and finish matters more than stone type.

    Faura · · 11 min read

    Bathroom lined in white Bianco Covelano marble, with a walk-in shower on a marble floor
    Bianco Covelano marble lining a bathroom and shower. Image: Margraf.

    In the UK, the slip resistance of stone is best judged by a wet pendulum test (a PTV of 36 or more means low slip potential), not by an R rating. R9–R13 ratings come from an oil-lubricated ramp test that does not convert to pendulum values, and each rating covers a wide range. Treat an R rating as a screening figure, then ask for a wet pendulum result on the exact finish you are specifying.

    This guide is for designers, architects, developers and contractors specifying stone for London projects. It explains what each rating measures, where specifiers go wrong, and why finish changes the outcome more than stone type does.

    TL;DR

    • R9–R13 is a shod ramp test using oil. It is not a measure of wet slip resistance, and R9 is the bottom of the scale, not a high score.
    • UK practice favours the pendulum: a wet PTV of 0–24 is high slip potential, 25–35 moderate, 36 or more low.
    • R, A–C, PTV and DCOF values cannot be converted into one another. Compare like with like.
    • Finish matters: in one granite study, polished stone fell to a wet PTV of 22 while flamed, brushed and grained finishes stayed above 36.
    • Specify the test method, slider, wet condition and finish on a production sample, and record the target in your spec.

    Table of contents

    What the R ratings actually measure

    The R scale comes from the German DIN 51130 ramp test. Two operators in standard boots walk forwards and backwards over an oil-coated surface on a ramp tilted a degree at a time until they slip. UKSRG describes the procedure and the angle bands it produces:

    Class Angle at which slipping occurs
    R9 6°–10°
    R10 over 10° to 19°
    R11 over 19° to 27°
    R12 over 27° to 35°
    R13 over 35°

    The barefoot version, DIN 51097, uses soapy water and gives classes A, B and C. OSHwiki notes that it suits wet barefoot areas such as pools and saunas, and that the ramp test is not suitable for use on site. Classes A to C are set at minimum angles of roughly 12°, 18° and 24°, as NBS tabulates.

    The misreading that catches specifiers

    NBS names the commonest specifier error as assuming the scale starts at R1, so that R9 looks like a high rating. In fact R9 is the lowest class, and NBS warns that R9 and sometimes R10 floors can be unacceptably slippery with some contaminants. A schedule that says only “R9” for a wet area says very little.

    Ratings are ranges, not pass marks

    UKSRG points out that each class covers a band. A surface at the top of R9 may perform little differently from one at the bottom of R10, so an R10 cannot be assumed suitable as a slip-resistant floor. It advises knowing how a product has performed in past applications and how the rating relates to the use, rather than treating the class as a pass.

    Why UK projects lean on the pendulum

    The portable pendulum drags a rubber slider across a wet surface and reports a Pendulum Test Value (PTV). UKSRG says the HSE and UKSRG recommend the pendulum for measuring floors in service, because ramp tests are carried out ex-factory, in a laboratory.

    The UKSRG risk bands, as reproduced by NBS, are:

    Wet PTV Slip potential
    0–24 High
    25–35 Moderate
    36 or more Low

    An academic study of the friction these tests measure links PTV roughly to the pendulum coefficient of friction × 100, and relates the bands to surface microroughness: below 10 µm Rz is high risk, 20 µm or more is low. A separate 2021 paper reports the HSE-linked assumption that slip probability is about 1 in 1,000,000 at SRV 36 or above, rising to about 1 in 20 below 24.

    Which standard applies now

    UKSRG explains that BS EN 16165:2021 has replaced BS 7976, BS EN 13893, DIN 51130 and DIN 51097. The new standard contains no R or A–C categories; in Germany, DIN EN 16165 keeps them through a national foreword. A UK specification that wants an R class therefore has to say so explicitly, and one that wants safety in wet conditions should ask for the pendulum method instead.

    For natural stone, BS EN 14231:2003 describes a pendulum test with slider 55 rubber, dry and wet, on six specimens tested in two directions at 180° to each other. Many stone data sheets quote this result, which is why the slider matters when you compare products.

    Two sliders, two purposes

    The EN 16165 pendulum offers slider 96 for shod areas and slider 57 as a compromise value. UKSRG advises that after an accident in service, the HSE would measure with slider 96 in a shod area and slider 55 in a barefoot area, so it can be prudent to test with both: one result to satisfy the product standard, one for the safety of the intended use.

    DCOF, A–C and the problem of comparing numbers

    Imported tile and stone literature often quotes DCOF, a value from a US test method. It is not a European standard, and nothing converts it into a UK PTV. UKSRG is equally clear about the ramp tests: the shod ramp uses oil with cleated boots, the barefoot ramp uses soapy water, and the pendulum uses water with a rubber slider. Because the conditions differ, the results cannot be correlated or converted.

    For a schedule of finishes, the rule is simple: compare values only when the method, contaminant and slider match, and treat anything else as a screening figure.

    The UK sets no statutory PTV for stone floors. The Workplace (Health, Safety and Welfare) Regulations 1992 require floors to be suitable for use, and the PTV bands above are the benchmark practitioners use. The duty holder or designer therefore sets a target for each location through a risk assessment. If your project has particular legal exposure, such as a public or commercial building, confirm the target with your health and safety adviser or building control.

    For tiled and stone floors, BSI published BS 5385-3:2024 in May 2024. It consolidates the former ceramic, mosaic, terrazzo, natural stone and agglomerated stone codes into one code of practice covering design, installation, protection from following trades and long-term cleaning and maintenance. Obtain the current document from BSI before quoting clauses in a specification.

    How finish changes the result

    Stone type alone does not decide slip resistance. Finish does most of the work.

    A 2021 peer-reviewed study of granite found that every finish reached SRV 36 or more when dry. Wet, polished tiles fell to 22, a very high slip risk, while flamed, brushed and grained slabs stayed above 36. Surface roughness rose from 1.85 µm for polished stone to 83.7 µm for grained. A dry result says almost nothing about a floor that will get wet.

    The NHS guidance in SHTM 61 adds two points designers often miss:

    • Smooth natural stone with low microroughness is unlikely to give satisfactory wet slip resistance, even with very light contamination. Dry dust or talc can have a similar effect to water.
    • Microroughness contributes more than visible patterning. Chequered or profiled surfaces can be slippery when wet and harder to keep clean than a smooth surface with the same microroughness.

    The same document notes that dampness left by wet cleaning is often enough to cause a slip, so your maintenance advice to the client is part of the slip specification.

    Pools, wet rooms and outdoor stone

    For poolside stone, Building Design reports that the Stone Federation GB’s 2024 swimming-pool guide recommends a minimum PTV of 40 for poolside surfaces, and that the finish (honed, flamed, tumbled or bush-hammered) decides whether that figure is reached. It also reports that marble, granite, quartzite and slate rate A for all pool situations, some limestones fall as low as D and sandstone E, and that external UK pool stone must pass freeze–thaw testing to BS EN 12371 over a minimum of 56 cycles.

    For a residential wet room or bathroom, treat a wet PTV of 36 or more as the starting target, then adjust it with a risk assessment covering who will use the room, whether they are barefoot, and likely contaminants such as soap and oils. Pair this with our guide to IP ratings for UK bathrooms when the same room has to meet both electrical and surface requirements.

    A specification routine that holds up

    1. Name the method. Call up a wet pendulum test to BS EN 16165 Annex C, with the current UKSRG guidelines for interpreting the result. If you need an R or A–C class for a particular reason, say so separately.
    2. Name the slider. Slider 96 for shod areas, slider 55 for barefoot areas. Consider requiring both, as UKSRG suggests.
    3. Test wet and state the contaminant. Water is the baseline; add soap or oil where the use demands it.
    4. Test the real finish. A result for a polished sample tells you nothing about the flamed version, and vice versa. Ask for a result on a production sample with the same finish, sealer and grout as the works, because treatments change the surface.
    5. Set a target and record why. A wet PTV of 36 or more is the low-risk band, but the number you write should come from the risk assessment for that room.
    6. Plan for in-service checks. Installation, early use, cleaning regimes and wear all change a surface, so agree who will check the laid floor and how it will be cleaned.
    7. Use a competent tester. Pendulum results depend on a trained operator and a calibrated instrument.

    The routine slots straight into a spec sheet. Our guide to FF&E specification writing shows how to lay out performance requirements so that procurement and installers cannot misread them.

    Worked example: a London hallway and a wet room

    Say you are specifying a limestone for a Mayfair townhouse. The entrance hall is dry most of the year but takes wet shoes in winter. The basement spa has a barefoot wet room.

    For the hall, a honed finish with a wet slider 96 PTV of 36 or more is a defensible target, with a note on mats and cleaning. For the spa, you would also want wet slider 55 results on the exact finish, and a rougher texture such as brushed or flamed rather than polished. A product sheet showing only “R10” would settle neither question, and a result for a polished sample would not carry across to the textured version.

    Our view

    Slip ratings are the part of stone specification where a single number most often hides the real question. We see the R scale treated as a pass mark when it is a range, and a dry result treated as evidence for a wet room.

    The habit we would encourage is to specify the finish and the test together. The finish is what you choose with your eye, and it also decides whether the floor grips, so the two should be judged in the same place at the same time.

    That is where a working trade showroom helps. When you can see stone finishes side by side, handle samples and read technical files in the same visit, you can set a surface against a target before the specification is issued, not after.

    Faura is a trade-only showroom and residency in Westminster for interior designers, architects, developers and contractors, with samples, technical files and a materials library in one place.

    — Faura Editorial

    Seeing the stone before you specify it

    Faura is a trade-only showroom in Westminster, open by appointment Monday to Friday, 09:00–18:00. Across two floors of finished interiors you can specify from over 200 brands, including natural stone and surfaces, with samples, technical files and a materials library to hand. To compare finishes against a slip-resistance target, start with our stone, tiles and finishes page, read our guide to stone, porcelain and marble for London projects, or arrange access through trade access. Trade terms are agreed individually with each approved trade account.

    Architects and developers can also look at specification support for larger schemes.

    FAQ

    What does an R11 rating mean for stone?

    R11 means the sample slipped at an angle of more than 19° and up to 27° on an oil-coated ramp in the DIN 51130 test. It is a mid-to-high class on that scale, but it is not a wet-floor guarantee, and it cannot be converted to a pendulum value. For a wet area, ask for a wet pendulum result on the actual finish.

    Is a PTV of 36 good enough for a bathroom floor?

    A wet PTV of 36 or more falls in the low slip potential band in the UKSRG guidelines, so it is the usual starting target. The number you finally specify should reflect a risk assessment of the room, including whether users are barefoot. For barefoot use, ask for results with slider 55.

    Can I convert an R rating or DCOF figure into a PTV?

    No. UKSRG states that the ramp and pendulum tests use different contaminants and footwear or sliders, so their results cannot be correlated or converted. DCOF comes from a US method and sits outside the European standards used in the UK.

    Does polished stone always fail slip tests?

    Not always, but finish is the main driver. In a published granite study, polished tiles dropped to a wet SRV of 22 while flamed, brushed and grained slabs stayed above 36. Always ask for results on the finish you intend to use, tested wet.

    Which standard should I cite in a UK specification?

    BS EN 16165:2021 has replaced BS 7976, DIN 51130 and DIN 51097, and its Annex C covers the pendulum. For natural stone product data, BS EN 14231:2003 is also used. Confirm the current wording with your health and safety adviser before finalising a project specification.

    Sources